Choosing What The Charts And Readouts Show
Summary
From Rostoc 0.4.9 each Machine decides which of its probes and readings each chart draws. In the Machine's Style & Colors settings every channel has Show in with two boxes: Roast Studio and Batch chart. Roast Studio draws the ones ticked for it; a saved roast's chart and a comparison draw the ones ticked for Batch chart. BT is always shown. Readouts, in the chart's ⋯ menu in Roast Studio, chooses up to four large values in the sidebar, BT and ET by default.
Steps
- To choose what a chart draws, open Machines, click Configure on the Machine, and open Style & Colors. Under each channel's Show in, tick Roast Studio, Batch chart, or both, then Save. BT's boxes are ticked and cannot be changed.
- A channel that is not ticked for a chart is not drawn and not listed in that chart's legend. When ET is not shown, its Rate of Rise and reference line go with it.
- To hide a line for a moment, click it in the chart legend; click again to bring it back. A legend click is for that chart only and does not change the Machine's settings. BT's entry cannot be unticked.
- To change the large values in Roast Studio's sidebar, open the ⋯ menu in the chart's corner and choose Readouts. Positions 1 and 2 are on top and 3 and 4 under them, one menu each. Every reading the Machine has is offered, even one hidden from the chart. Picking a value already placed swaps the two; None empties a position.
- Click Save to keep the Readouts, Cancel to leave them, or Reset to put BT and ET back in 1 and 2 (kept on Save). Readouts are kept for each Machine with the account.
- Gas, airflow and drum values show their unit, such as mbar, RPM or %, in Readouts and in the chart tooltip.
- A saved roast's chart has Chart style in its … menu, to restyle each channel, as Roast Studio does.