Does Rostoc support the Atilla Coffee Roasters Atilla GOLD plus II Control Auto?

Yes - Atilla Coffee Roasters Atilla GOLD plus II Control Auto is supported by Rostoc via Modbus TCP over Ethernet (port 502). This Machine can be connected for real-time roast logging, Curve recording, and roast analysis. For eligible accounts, Rostoc can also control the functions listed below.

Connection setup

The Atilla Coffee Roasters Atilla GOLD plus II Control Auto connects to Rostoc via Modbus TCP over Ethernet (port 502).Connection: Ethernet.

Setup steps

Option A: Router or local network

  1. Connect the roaster with Ethernet.
  2. Connect your computer to the same network by Wi-Fi or Ethernet.
  3. Find the roaster IP address on the machine display, controller screen, manual, or router device list.

Option B: Direct Ethernet cable

  1. Connect Ethernet directly from the roaster to your computer.
  2. If the roaster uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
  3. Set your computer Ethernet IPv4 address manually in the same subnet as the roaster. Use the same subnet mask as the machine and choose a different IP address.
  4. For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
  5. Leave gateway and DNS blank unless the machine manual gives values.

Finish in Rostoc

  1. Open Rostoc and go to Settings → Machines.
  2. Click + Add Machine and choose Browse Catalogue.
  3. Find "Atilla Coffee Roasters Atilla GOLD plus II Control Auto" in the catalog and click Add.
  4. In the machine settings, enter the roaster IP address. Do not enter the computer's static IP address.
  5. Verify the TCP port (default: 502) and unit ID if the machine page or manual shows one.
  6. Click Connect — Rostoc will read all configured data streams automatically.

Troubleshooting

Rostoc cannot connect
Check that the IP address in Rostoc matches the roaster IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
Direct cable setup is unclear
Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
IP address changed after restart
A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
Connection refused or timed out
Verify the machine is powered on and no firewall is blocking TCP port 502.
Data reads return zeros
Confirm the Modbus unit ID matches the roaster's configuration. Some models require a specific unit ID (slave address).
Intermittent disconnections
Use a wired Ethernet connection instead of Wi-Fi. Check cable integrity and switch/router stability.

Machine controls

Machine controls available

Eligible accounts can send the following commands while this Machine is connected and selected. Availability does not certify every control on the physical Machine; test safely before production use.

Connection: Atilla Atilla GOLD plus II Control Auto · Ethernet

Machine-specific control previewAtilla GOLD plus II Control Auto
Interactive documentation demo
Atilla Atilla GOLD plus II Control Auto · Ethernet

Adjustable controls

50%
50rpm
50%

Documentation demo only. Values are illustrative; this preview never connects to a Machine or sends a command.
ControlHow it worksRostoc command valuesResult check
AirOutputSliderAdjust, then release0–100 %Connection acknowledgement; verify on the Machine
DrumOutputSliderAdjust, then release0–100 rpmConnection acknowledgement; verify on the Machine
BurnerOutputSliderAdjust, then release0–100 %Connection acknowledgement; verify on the Machine

These are Rostoc's accepted command values for this connection, not certified safe operating limits. Follow the Machine manufacturer's limits and procedures.

Specifications

Roaster typeDrum
HeatingUnknown
Setup typeModbus
ConnectionEthernet

Data streams

When connected, Rostoc reads the following data from this machine:

  • auto
  • Bean Tempcelsius
  • Env Tempcelsius
  • Drum Tempcelsius
  • Burner Setpointpercent
  • Drum Speedrpm
  • Fan Setpointpercent