Ir al contenido

Diedrich Roasters Diedrich DR: Machine controls y configuración Modbus TCP

Compatiblede Diedrich Roasters

¿Rostoc es compatible con Diedrich Roasters Diedrich DR?

Sí - Diedrich Roasters Diedrich DR es compatible con Rostoc via Modbus TCP over Ethernet (port 8010). Esta máquina puede conectarse para registrar datos de tueste en tiempo real, registrar la Curve y analizar el tueste. En las cuentas elegibles, Rostoc también puede controlar las funciones indicadas más abajo.

Configuración de conexión

Diedrich Roasters Diedrich DR se conecta a Rostoc via Modbus TCP over Ethernet (port 8010).Conexión: Ethernet.

Pasos de configuración

Option A: Router or local network

  1. Connect the roaster with Ethernet.
  2. Connect your computer to the same network by Wi-Fi or Ethernet.
  3. Find the roaster IP address on the machine display, controller screen, manual, or router device list.

Option B: Direct Ethernet cable

  1. Connect Ethernet directly from the roaster to your computer.
  2. If the roaster uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
  3. Set your computer Ethernet IPv4 address manually in the same subnet as the roaster. Use the same subnet mask as the machine and choose a different IP address.
  4. For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
  5. Leave gateway and DNS blank unless the machine manual gives values.

Finish in Rostoc

  1. Open Rostoc and go to Settings → Machines.
  2. Click + Add Machine and choose Browse Catalogue.
  3. Find "Diedrich Roasters Diedrich DR" in the catalog and click Add.
  4. In the machine settings, enter the roaster IP address. Do not enter the computer's static IP address.
  5. Verify the TCP port (default: 502) and unit ID if the machine page or manual shows one.
  6. Click Connect — Rostoc will read all configured data streams automatically.

Solución de problemas

Rostoc cannot connect
Check that the IP address in Rostoc matches the roaster IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
Direct cable setup is unclear
Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
IP address changed after restart
A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
Connection refused or timed out
Verify the machine is powered on and no firewall is blocking TCP port 502.
Data reads return zeros
Confirm the Modbus unit ID matches the roaster's configuration. Some models require a specific unit ID (slave address).
Intermittent disconnections
Use a wired Ethernet connection instead of Wi-Fi. Check cable integrity and switch/router stability.

Controles de la máquina

Controles de la máquina disponibles

Las cuentas elegibles pueden enviar estos comandos cuando la máquina esté conectada y seleccionada. Prueba los controles con seguridad antes de usarlos en producción.

Conexión: Diedrich Diedrich DR · Ethernet

Vista previa de controles específicos de la máquinaDiedrich DR
Demostración interactiva de la documentación
Diedrich Diedrich DR · Ethernet

Controles ajustables

50%
50%

Solo demostración de la documentación. Los valores son ilustrativos; esta vista previa nunca se conecta a una máquina ni envía comandos.
ControlCómo funcionaValores de comando de RostocComprobación del resultado
AirSalidaDeslizadorAjustar y soltar0–100 %Confirmación de la conexión; verificar en la máquina
BurnerSalidaDeslizadorAjustar y soltar0–100 %Confirmación de la conexión; verificar en la máquina

Estos son los valores de comando que acepta Rostoc para esta conexión, no límites operativos seguros certificados. Sigue los límites y procedimientos del fabricante.

Especificaciones

Tipo de tostadoraDrum
CalentamientoUnknown
Tipo de configuraciónModbus
ConexiónEthernet

Flujos de datos

Cuando está conectada, Rostoc lee los siguientes datos de esta máquina:

  • Bean Tempfahrenheit
  • Inlet Tempfahrenheit
  • Env Tempfahrenheit
  • Burner Setpointpercent
  • Fan Setpointpercent