Compatibilidad experimental de Rostoc con Prisma Coffee Tech Prisma PLC
¿Rostoc es compatible con Prisma Coffee Tech Prisma PLC?
Rostoc lista compatibilidad experimental para Prisma Coffee Tech Prisma PLC over Ethernet. Esta máquina puede conectarse para registrar datos de tueste en tiempo real, registrar la Curve y analizar el tueste. Confirma la configuración antes de depender de ella en producción.
Configuración de conexión
Prisma Coffee Tech Prisma PLC se conecta a Rostoc over Ethernet.Conexión: Ethernet.
Pasos de configuración
Option A: Router or local network
- Connect the roaster with Ethernet.
- Connect your computer to the same network by Wi-Fi or Ethernet.
- Find the roaster IP address on the machine display, controller screen, manual, or router device list.
Option B: Direct Ethernet cable
- Connect Ethernet directly from the roaster to your computer.
- If the roaster uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
- Set your computer Ethernet IPv4 address manually in the same subnet as the roaster. Use the same subnet mask as the machine and choose a different IP address.
- For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
- Leave gateway and DNS blank unless the machine manual gives values.
Finish in Rostoc
- Open Rostoc and go to Settings → Machines.
- Click + Add Machine and choose Browse Catalogue.
- Find "Prisma Coffee Tech Prisma PLC" in the catalog and click Add.
- In the machine settings, enter the roaster IP address. Do not enter the computer's static IP address.
- Click Connect to begin logging.
Solución de problemas
- Rostoc cannot connect
- Check that the IP address in Rostoc matches the roaster IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
- Direct cable setup is unclear
- Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
- IP address changed after restart
- A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
Controles de la máquina
Solo registro de datos
Rostoc puede leer esta máquina para registrar el tueste, pero actualmente no ofrece controles para ella.
Consulta la disponibilidad y la seguridad en Controles de la máquina.
Especificaciones
| Tipo de tostadora | Drum |
|---|---|
| Calentamiento | Unknown |
| Tipo de configuración | Prisma network |
| Conexión | Ethernet |
Flujos de datos
Cuando está conectada, Rostoc lee los siguientes datos de esta máquina:
- Blowerpercent
- Bean Tempcelsius
- Burnerpercent
- Drumpercent
- Env Tempcelsius