  1. Connect a USB-to-RS-485 adapter to your computer, then connect the adapter to the machine RS-485 port or terminals.
  2. Match the A/B or +/− wiring to the machine manual. If the adapter has ground, connect it only when the manual recommends it.
  3. Install the adapter driver if your operating system requires it.
  4. Open Rostoc and go to Settings → Machines.
  5. Click + Add Machine and choose Browse Catalogue.
  6. Find "Craftsmith Craft" in the catalog and click Add.
  7. Back on the main screen, click Use for the Machine if needed, then choose the serial port assigned to the adapter. The baud rate, serial settings, and unit ID are pre-filled from the catalog.
  8. Close other roasting software that may be using the same adapter.
  9. Click Connect to start reading data.

Solución de problemas

Serial port not detected
Ensure the USB-to-RS-485 adapter driver is installed. Try a different USB port. On macOS, check System Information > USB.
No response from roaster
Verify the baud rate and parity settings match the roaster's configuration. Check RS-485 wiring polarity (A/B or +/−).
CRC errors in log
Reduce cable length or add a termination resistor. Ensure no other device shares the RS-485 bus.
Another app is open
Close other roasting software that may be using the same serial adapter before connecting in Rostoc.

Controles de la máquina

Solo registro de datos

Rostoc puede leer esta máquina para registrar el tueste, pero actualmente no ofrece controles para ella.

Especificaciones

Tipo de tostadoraDrum
CalentamientoUnknown
Tipo de configuraciónModbus
ConexiónRS-485 Serial (USB)

Flujos de datos

Cuando está conectada, Rostoc lee los siguientes datos de esta máquina:

  • Bean Tempcelsius
  • Env Tempcelsius