Bühler AG Bühler RM 20 Playone: configuración Siemens S7 con Rostoc

Compatiblede Bühler AG

¿Rostoc es compatible con Bühler AG Bühler RM 20 Playone?

Sí - Bühler AG Bühler RM 20 Playone es compatible con Rostoc via Siemens S7 protocol over Ethernet. Esta tostadora drum de 20 kg puede conectarse para registrar datos de tueste en tiempo real, registrar la Curve y analizar el tueste.

Configuración de conexión

Bühler AG Bühler RM 20 Playone se conecta a Rostoc via Siemens S7 protocol over Ethernet.Conexión: Ethernet.

Pasos de configuración

Option A: Router or local network

  1. Connect the PLC with Ethernet.
  2. Connect your computer to the same network by Wi-Fi or Ethernet.
  3. Find the PLC IP address on the machine display, controller screen, manual, or router device list.

Option B: Direct Ethernet cable

  1. Connect Ethernet directly from the PLC to your computer.
  2. If the PLC uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
  3. Set your computer Ethernet IPv4 address manually in the same subnet as the PLC. Use the same subnet mask as the machine and choose a different IP address.
  4. For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
  5. Leave gateway and DNS blank unless the machine manual gives values.

Finish in Rostoc

  1. Open Rostoc and go to Settings → Machines.
  2. Click + Add Machine and choose Browse Catalogue.
  3. Find "Bühler AG Bühler RM 20 Playone" in the catalog and click Add.
  4. In the machine settings, enter the PLC IP address. Do not enter the computer's static IP address.
  5. Verify any PLC rack, slot, or access details shown in the machine page or provided by the manufacturer.
  6. Click Connect — Rostoc handles the S7 protocol automatically.

Solución de problemas

Rostoc cannot connect
Check that the IP address in Rostoc matches the PLC IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
Direct cable setup is unclear
Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
IP address changed after restart
A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
Connection refused
Verify the PLC IP address and ensure the computer can ping it. Check that S7 communication is enabled on the PLC.
Data block access denied
The PLC may require access permissions. Contact the machine manufacturer for the correct DB/rack/slot configuration.

Controles de la máquina

Solo registro de datos

Rostoc puede leer esta máquina para registrar el tueste, pero actualmente no ofrece controles para ella.

Especificaciones

Tipo de tostadoraDrum
CalentamientoUnknown
Capacidad20 kg
Tipo de configuraciónSiemens S7
ConexiónEthernet

Flujos de datos

Cuando está conectada, Rostoc lee los siguientes datos de esta máquina:

  • Bean Tempcelsius
  • Env Tempcelsius
  • Inlet Tempcelsius
  • IT SPcelsius
  • Pressurembar
  • stateraw
  • Drum Speedrpm
  • Fan Setpointpercent
  • Ambient Tempcelsius