Pular para o conteúdo

Diedrich Roasters Diedrich CR: Machine controls e configuração Modbus TCP

Compatívelpor Diedrich Roasters

O Rostoc é compatível com Diedrich Roasters Diedrich CR?

Sim - Diedrich Roasters Diedrich CR é compatível com o Rostoc via Modbus TCP over Ethernet (port 8010). Esta máquina pode ser conectada para registro de dados de torra em tempo real, registro da Curve e análise da torra. Em contas elegíveis, o Rostoc também pode controlar as funções listadas abaixo.

Configuração de conexão

Diedrich Roasters Diedrich CR se conecta ao Rostoc via Modbus TCP over Ethernet (port 8010).Conexão: Ethernet.

Passos de configuração

Option A: Router or local network

  1. Connect the roaster with Ethernet.
  2. Connect your computer to the same network by Wi-Fi or Ethernet.
  3. Find the roaster IP address on the machine display, controller screen, manual, or router device list.

Option B: Direct Ethernet cable

  1. Connect Ethernet directly from the roaster to your computer.
  2. If the roaster uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
  3. Set your computer Ethernet IPv4 address manually in the same subnet as the roaster. Use the same subnet mask as the machine and choose a different IP address.
  4. For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
  5. Leave gateway and DNS blank unless the machine manual gives values.

Finish in Rostoc

  1. Open Rostoc and go to Settings → Machines.
  2. Click + Add Machine and choose Browse Catalogue.
  3. Find "Diedrich Roasters Diedrich CR" in the catalog and click Add.
  4. In the machine settings, enter the roaster IP address. Do not enter the computer's static IP address.
  5. Verify the TCP port (default: 502) and unit ID if the machine page or manual shows one.
  6. Click Connect — Rostoc will read all configured data streams automatically.

Solução de problemas

Rostoc cannot connect
Check that the IP address in Rostoc matches the roaster IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
Direct cable setup is unclear
Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
IP address changed after restart
A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
Connection refused or timed out
Verify the machine is powered on and no firewall is blocking TCP port 502.
Data reads return zeros
Confirm the Modbus unit ID matches the roaster's configuration. Some models require a specific unit ID (slave address).
Intermittent disconnections
Use a wired Ethernet connection instead of Wi-Fi. Check cable integrity and switch/router stability.

Controles da máquina

Controles da máquina disponíveis

Contas elegíveis podem enviar estes comandos quando a máquina estiver conectada e selecionada. Teste com segurança antes do uso em produção.

Conexão: Diedrich Diedrich CR · Ethernet

Prévia dos controles específicos da máquinaDiedrich CR
Demonstração interativa da documentação
Diedrich Diedrich CR · Ethernet

Controles ajustáveis

50%
50%

Somente demonstração da documentação. Os valores são ilustrativos; esta prévia nunca se conecta a uma máquina nem envia comandos.
ControleComo funcionaValores de comando do RostocVerificação do resultado
AirSaídaControle deslizanteAjustar e soltar0–100 %Confirmação da conexão; verifique na máquina
BurnerSaídaControle deslizanteAjustar e soltar0–100 %Confirmação da conexão; verifique na máquina

Estes são os valores de comando aceitos pelo Rostoc para esta conexão, não limites operacionais seguros certificados. Siga os limites e procedimentos do fabricante.

Especificações

Tipo de torradorDrum
AquecimentoUnknown
Tipo de setupModbus
ConexãoEthernet

Fluxos de dados

Quando conectado, o Rostoc lê os seguintes dados desta máquina:

  • Bean Tempfahrenheit
  • Inlet Tempfahrenheit
  • Env Tempfahrenheit
  • Burner Setpointpercent
  • Fan Setpointpercent