O Rostoc é compatível com Petroncini Impianti S.p.A. Petroncini Maestro i06?

Sim - Petroncini Impianti S.p.A. Petroncini Maestro i06 é compatível com o Rostoc via Siemens S7 protocol over Ethernet. Esta máquina pode ser conectada para registro de dados de torra em tempo real, registro da Curve e análise da torra.

Configuração de conexão

Petroncini Impianti S.p.A. Petroncini Maestro i06 se conecta ao Rostoc via Siemens S7 protocol over Ethernet.Conexão: Ethernet.

Passos de configuração

Option A: Router or local network

  1. Connect the PLC with Ethernet.
  2. Connect your computer to the same network by Wi-Fi or Ethernet.
  3. Find the PLC IP address on the machine display, controller screen, manual, or router device list.

Option B: Direct Ethernet cable

  1. Connect Ethernet directly from the PLC to your computer.
  2. If the PLC uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
  3. Set your computer Ethernet IPv4 address manually in the same subnet as the PLC. Use the same subnet mask as the machine and choose a different IP address.
  4. For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
  5. Leave gateway and DNS blank unless the machine manual gives values.

Finish in Rostoc

  1. Open Rostoc and go to Settings → Machines.
  2. Click + Add Machine and choose Browse Catalogue.
  3. Find "Petroncini Impianti S.p.A. Petroncini Maestro i06" in the catalog and click Add.
  4. In the machine settings, enter the PLC IP address. Do not enter the computer's static IP address.
  5. Verify any PLC rack, slot, or access details shown in the machine page or provided by the manufacturer.
  6. Click Connect — Rostoc handles the S7 protocol automatically.

Solução de problemas

Rostoc cannot connect
Check that the IP address in Rostoc matches the PLC IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
Direct cable setup is unclear
Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
IP address changed after restart
A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
Connection refused
Verify the PLC IP address and ensure the computer can ping it. Check that S7 communication is enabled on the PLC.
Data block access denied
The PLC may require access permissions. Contact the machine manufacturer for the correct DB/rack/slot configuration.

Controles da máquina

Somente registro de dados

O Rostoc pode ler esta máquina para registrar a torra, mas não oferece controles ao vivo.

Especificações

Tipo de torradorDrum
AquecimentoUnknown
Tipo de setupSiemens S7
ConexãoEthernet

Fluxos de dados

Quando conectado, o Rostoc lê os seguintes dados desta máquina:

  • Bean Tempcelsius
  • Env Tempcelsius
  • Burnercelsius
  • Gas Setpointpercent
  • Airflowpercent
  • DrumSpeedpercent