Giesen Coffee Roasters Giesen W60A: Machine controls dan setup Siemens S7
Apakah Rostoc mendukung Giesen Coffee Roasters Giesen W60A?
Ya - Giesen Coffee Roasters Giesen W60A didukung oleh Rostoc via Siemens S7 protocol over Ethernet. Mesin sangrai drum 60 kg ini dapat dihubungkan untuk logging data roasting secara real-time, merekam Curve, dan analisis roasting. Untuk akun yang memenuhi syarat, Rostoc juga dapat mengontrol fungsi yang tercantum di bawah.
Setup koneksi
Giesen Coffee Roasters Giesen W60A terhubung ke Rostoc via Siemens S7 protocol over Ethernet.Koneksi: Ethernet.
Langkah setup
Option A: Router or local network
- Connect the PLC with Ethernet.
- Connect your computer to the same network by Wi-Fi or Ethernet.
- Find the PLC IP address on the machine display, controller screen, manual, or router device list.
Option B: Direct Ethernet cable
- Connect Ethernet directly from the PLC to your computer.
- If the PLC uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
- Set your computer Ethernet IPv4 address manually in the same subnet as the PLC. Use the same subnet mask as the machine and choose a different IP address.
- For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
- Leave gateway and DNS blank unless the machine manual gives values.
Finish in Rostoc
- Open Rostoc and go to Settings → Machines.
- Click + Add Machine and choose Browse Catalogue.
- Find "Giesen Coffee Roasters Giesen W60A" in the catalog and click Add.
- In the machine settings, enter the PLC IP address. Do not enter the computer's static IP address.
- Verify any PLC rack, slot, or access details shown in the machine page or provided by the manufacturer.
- Click Connect — Rostoc handles the S7 protocol automatically.
Pemecahan masalah
- Rostoc cannot connect
- Check that the IP address in Rostoc matches the PLC IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
- Direct cable setup is unclear
- Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
- IP address changed after restart
- A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
- Connection refused
- Verify the PLC IP address and ensure the computer can ping it. Check that S7 communication is enabled on the PLC.
- Data block access denied
- The PLC may require access permissions. Contact the machine manufacturer for the correct DB/rack/slot configuration.
Kontrol mesin
Akun yang memenuhi syarat dapat mengirim perintah ini saat mesin terhubung dan dipilih. Uji dengan aman sebelum penggunaan produksi.
Koneksi: Giesen Giesen W60A · Ethernet
Kontrol yang dapat disesuaikan
Sakelar dan tindakan
| Kontrol | Cara kerja | Nilai perintah Rostoc | Pemeriksaan hasil |
|---|---|---|---|
| MACHINETindakan sesaat | Sakelar nyala/matiNyalakan atau matikan | Off / On | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
| Underpressure SetpointSetpoint | SliderSesuaikan lalu lepaskan | 100–170 Pa | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
| DrumOutput | SliderSesuaikan lalu lepaskan | 40–55 Hz | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
| SPSetpoint | SliderSesuaikan lalu lepaskan | 0–280 °C | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
| BurnerOutput | SliderSesuaikan lalu lepaskan | 0–100 % | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
| DischargeTindakan roasting | Tombol tindakanKlik sekali | Mengirim satu tindakan | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
| LIGHTStatus | Sakelar nyala/matiNyalakan atau matikan | Off / On | Dikonfirmasi oleh koneksi; verifikasi pada mesin |
Ini adalah nilai perintah yang diterima Rostoc untuk koneksi ini, bukan batas operasi aman yang tersertifikasi. Ikuti batas dan prosedur produsen mesin.
Pelajari ketersediaan dan keamanan di Kontrol mesin. Untuk berpindah kontrol tanpa mouse, lihat Pintasan keyboard.
Spesifikasi
| Tipe roaster | Drum |
|---|---|
| Pemanasan | Hybrid |
| Kapasitas | 60 kg |
| Tipe setup | Siemens S7 |
| Koneksi | Ethernet |
Aliran data
Saat terhubung, Rostoc membaca data berikut dari mesin ini:
- Bean Tempcelsius
- Env Tempcelsius
- Burner Powerpercent
- UnderpressurePa
- Drum SpeedHz
- Temperature Setpointcelsius
- Burner Setpointpercent
- Underpressure SetpointPa
- Fan Speedpercent