Kompatibilitas eksperimental Rostoc dengan Probat Sample
Apakah Rostoc mendukung Probat Sample?
Rostoc mencantumkan kompatibilitas eksperimental untuk Probat Sample over Ethernet. Mesin sangrai drum 0.2 kg ini dapat dihubungkan untuk logging data roasting secara real-time, merekam Curve, dan analisis roasting. Konfirmasi setup sebelum mengandalkannya untuk logging produksi.
Setup koneksi
Probat Sample terhubung ke Rostoc over Ethernet.Koneksi: Ethernet.
Langkah setup
Option A: Router or local network
- Connect the roaster with Ethernet.
- Connect your computer to the same network by Wi-Fi or Ethernet.
- Find the roaster IP address on the machine display, controller screen, manual, or router device list. On many Probat P Series machines, check Preferences → General; on some Probatone Series II machines, use the network or radio icon.
Option B: Direct Ethernet cable
- Connect Ethernet directly from the roaster to your computer.
- If the roaster uses automatic network addressing, change it to a manual/static IP first or reserve its address in the router before disconnecting from that router.
- Set your computer Ethernet IPv4 address manually in the same subnet as the roaster. Use the same subnet mask as the machine and choose a different IP address.
- For mask 255.255.255.0, usually keep the first three IP blocks the same and change the last one. For mask 255.255.0.0, keep the first two IP blocks and choose another address in that range.
- Leave gateway and DNS blank unless the machine manual gives values.
Finish in Rostoc
- Open Rostoc and go to Settings → Machines.
- Click + Add Machine and choose Browse Catalogue.
- Find "Probat Sample" in the catalog and click Add.
- In the machine settings, enter the roaster IP address. Do not enter the computer's static IP address.
- Click Connect to begin logging.
Pemecahan masalah
- Rostoc cannot connect
- Check that the IP address in Rostoc matches the roaster IP address. If you use a router, confirm the computer is on the same local network. If you use a direct cable, confirm the computer and machine use the same subnet mask and different IP addresses in that subnet.
- Direct cable setup is unclear
- Use a manual IPv4 address on the computer. For a machine at 10.20.0.211 with mask 255.255.255.0, use 10.20.0.42 with that same mask. If the machine uses 255.255.0.0, keep that mask and choose another 10.20.x.x address. Leave gateway/DNS blank unless the machine manual gives values.
- IP address changed after restart
- A router can assign a new address automatically. Check the machine display or router again, or reserve the machine address in your router.
- Older Probatone network conflict
- Some Probatone II/Wago small-touch-panel setups can conflict with routers using 192.168.2.x. Use a different router address range or ask Probat/your network admin.
Kontrol mesin
Hanya logging data
Rostoc dapat membaca mesin ini untuk logging roasting, tetapi belum menyediakan kontrol langsung.
Pelajari ketersediaan dan keamanan di Kontrol mesin.
Spesifikasi
| Tipe roaster | Drum |
|---|---|
| Pemanasan | Electric |
| Kapasitas | 0.2 kg |
| Tipe setup | Probat Ethernet |
| Koneksi | Ethernet |
Aliran data
Saat terhubung, Rostoc membaca data berikut dari mesin ini:
- Air Pressurembar
- Bean Tempcelsius
- Burnerpercent
- Burner State
- Cooling Fan State
- Drives State
- Env Tempcelsius
- Exhaust Air RoRcelsius_per_min
- Standby State
- Stirrer State